Electric fan aerodynamic force specific property tests should according to GB/T 1236-2000 about ” Industrial fan Wind road standardized performance tests ” the middle standard admission state is in progress, electric fan noise measurement is according to GB/T2888-1991 abort ” fan and roots blower measurement method ” the standard is in progress. The measurement value is for the parameter

Few Model for Reference

Type Flow volume Total pressure Noise Rated- speed Rating power Current Start Current Input power
(m3/h) (Pa) dB(A) (r/min) (kw) (A) (A) (KW)
DBF-4QDBF-4HCFZ-4Q 6 A 3600 90 53 960 0. 25 1.3 5.9 0. 253
B 4600 100 55 960 0. 25 1.3 5.9 0. 33
CFZ-4H A 2800 60 51 720 0. 18 1.1 4.3 0. 184
B 3500 70 53 720 0. 18 1.1 4.3 0. 198
DBF-5QDBF-5HCFZ-5Q 6 A 4500 60 59 960 0. 37 1.2 4 0. 38
B 5800 70 62 960 0. 37 1.2 4 0. 396
CFZ-5H C 7500 90 64 960 0. 37 1.2 4 0. 406
8 A 3600 55 55 720 0. 25 1.1 3 0. 255
B 4800 64 56 720 0. 25 1.1 3 0. 269
C 5800 70 58 720 0. 25 1.1 3 0. 281
10 A 3200 27 52 580 0. 18 1.1 3 0. 198
B 3600 30 54 580 0. 18 1.1 3 0. 22
C 4240 35 55 580 0. 18 1.1 3 0. 253
DBF-6. 3QDBF-6. 3HCFZ-6. 3Q 6 A 7500 80 63 960 0. 55 1.6 5.5 0. 55
B 9800 90 64 960 0. 55 1.6 5.5 0. 649
CFZ-6. 3H C 10800 110 65 960 0. 55 1.6 5.5 0. 737
8 A 6400 60 59 720 0. 37 1.4 5 0. 374
B 7200 65 60 720 0. 37 1.4 5 0.418
C 8000 70 61 720 0. 37 1.4 5 0. 484
10 A 5600 50 54 580 0. 25 1.1 3 0. 256
B 6200 53 56 580 0. 25 1.1 3 0. 281
C 7000 55 58 580 0. 25 1.1 3 0. 325
DBF-7QDBF-7HCFZ-7Q 8 A 10500 100 61 720 0. 55 1.9 4.5 0. 66
B 11500 95 62 720 0. 55 1.9 4.5 0. 781
CFZ-7H C 13000 90 64 720 0. 55 1.9 4.5 0.815
10 A 7500 60 56 580 0. 25 1. 1 3 0. 33
B 9000 70 60 580 0. 25 1. 1 3 0. 363
C 10000 65 62 580 0. 25 1. 1 3 0. 374
12 A 8200 45 54 480 0. 37 1.6 4 0. 372
B 8600 45 54 480 0. 37 1.6 4 0. 385
C 9000 50 55 480 0. 37 1.6 4 0. 407

 

Drawing2

Drawing

 

 


Product detail pictures:

New Fashion Design for Transformer Oil Filtration Machine -
  Dry Transformer Cooling Fan – Trihope detail pictures

New Fashion Design for Transformer Oil Filtration Machine -
  Dry Transformer Cooling Fan – Trihope detail pictures

New Fashion Design for Transformer Oil Filtration Machine -
  Dry Transformer Cooling Fan – Trihope detail pictures

New Fashion Design for Transformer Oil Filtration Machine -
  Dry Transformer Cooling Fan – Trihope detail pictures

New Fashion Design for Transformer Oil Filtration Machine -
  Dry Transformer Cooling Fan – Trihope detail pictures


Related Product Guide:

New Fashion Design for Transformer Oil Filtration Machine - Dry Transformer Cooling Fan – Trihope , The product will supply to all over the world, such as: , , ,

  • 5 Stars By from -

    5 Stars By from -
    Write your message here and send it to us